Lunaire Stability Chamber

Product details

Lunaire’s stability chambers are available in four convenient workspace sizes of 8, 16, 32, and 58-cubic-feet with a variety of temperature and humidity combinations, these climate control chambers provide the flexibility for a wide range of uses. These high-performance stability chambers use a highly efficient design with a horizontal airflow system that provides maximum uniformity.

Lunaire stability chambers are commonly used for testing applications that include ICH guidelines, accelerated shelf-life studies, steady-state, stability, package testing, burn-in, curing, controlled temperature storage, and biomedical research among many others. Lunaire test chambers can be configured as intrinsically safe to allow for some hazardous materials testing applications.

Stability Chamber Performance

  • Temperature Range: 0 °C to + 99 °C, ± 0.3 °C after stabilization
  • Temperature/Humidity Range: 20% to 95% RH in the dry bulb range of +20°C to +85°C, limited by a 5°C dewpoint

Learn About Reverse Osmosis Options

Lunaire’s stability chambers are available in four convenient workspace sizes of 8, 16, 32, and 58-cubic-feet with a variety of temperature and humidity combinations, these climate control chambers provide the flexibility for a wide range of uses. These high-performance stability chambers use a highly efficient design with a horizontal airflow system that provides maximum uniformity.

Lunaire stability chambers are commonly used for testing applications that include ICH guidelines, accelerated shelf-life studies, steady-state, stability, package testing, burn-in, curing, controlled temperature storage, and biomedical research among many others. Lunaire test chambers can be configured as intrinsically safe to allow for some hazardous materials testing applications.

Stability Chamber Performance

  • Temperature Range: 0 °C to + 99 °C, ± 0.3 °C after stabilization
  • Temperature/Humidity Range: 20% to 95% RH in the dry bulb range of +20°C to +85°C, limited by a 5°C dewpoint

Learn About Reverse Osmosis Options

Benefits

  • Meets a variety of needs with availability in four sizes and multiple temperature and humidity combinations
  • Temperature/humidity settings are housed conveniently in one controller and allow for hands-free operation
  • Designed for quick shipping, easy installation, and consistency over controls, utility requirements, and heat output
  • Air intake and exhaust tubes with manual dampers vent undesirable process moisture and vapors, protecting the product
  • The highly efficient airflow system in the Lunaire Steady State Stability Test Chamber provides maximum temperature uniformity in testing
  • Safety-minded low limit and high limit temperature shutdown circuits sound, limiting unwanted results

Features

  • Electric Incoloy-sheathed tubular heaters
  • Single stage reciprocating type compressor with Non-CFC refrigerant
  • Vapor-Flo V Humidity Generator
  • Centrifugal type blower wheel with external mounted motor for air circulation
  • Door Gasket Trough and Chamber Drain
  • Non-ramping, manual mode
  • Direct printing to a serial printer
  • Direct connection to a PLC or computer workstation
  • High definition, LCD display with four digital input lines
  • Solid Shelves included

Lunaire CEO Model Numbers

  • CEO 908-2
  • CEO 908-4
  • CEO 916-2
  • CEO 916-4
  • CEO 932-2
  • CEO 932-4
  • CEO 958-2
  • CEO 958-4

Options

  • RS 232 or RS485 communications
  • Data logging and graphical trend chart for Watlow F4T controller
  • 5 gallon water reservoir**
  • Recirculating system for humidity water**
  • Water demineralizer**
  • Reverse osmosis system**
  • Condensate pump**
  • External dryer for obtaining humidity levels as low as 5%**
  • Additional ports
  • Additional stainless steel shelves
  • Stainless steel exterior
  • Heated viewing window
  • Interior lighting
  • Recording Instruments
  • OTP high limit control
  • Interior non-sealed Lexan door
  • Interior vapor proof duplex receptacle
  • NIST Calibration
  • Tenney Environmental offers calibration services accredited to the ISO 17025 standard
  • Additional engineered to order custom configurations available

* Consult your Tenney/Lunaire Environmental Sales Representative for a full list of available options.

** Humidity models only

Stability Chamber Specifications

 Chamber Specifications
Click to see full-sized spec sheet

Tenney_Watlow F4T Controller
Watlow F4T Temperature Controller

The Watlow F4T Temperature Controller with INTUITION™ temperature process controller combines the flexibility of a modular I/O controller with best-in-class ease of use.

Features

  • 4.3-inch, color touch panel with high-resolution, graphical user-interface
  • 1 to 4 control loops with TRU-TUNE+ adaptive control algorithm for superior controllability
  • 40 ramp and soak profiles with real-time clock and battery backup.
  • Ethernet Modbus® TCP connectivity
  • High-speed USB 2.0 host port
  • Modular design, which offers numerous types of field pluggable modules for maximum flexibility and easiest compatibility
  • Data Logging capability
  • Graphical Trend Chart
  • TPS provides panel mounted USB and Ethernet ports located on the front control panel of the equipment

   

Not the product you're looking for?

Our product finder tool will help you search for the exact specifications you require.

Product Finder

Lunaire Stability Chamber
Lunaire CEO 958 Stability Chamber
Lunaire CEO 908 Stability Chamber
Slide 1 of 3
Lunaire Stability Chamber
Lunaire CEO 958 Stability Chamber
Lunaire CEO 908 Stability Chamber