Info & pricing
570-538-7200
tpsinfo@tps.spx.com
|
|
1500° Box Furnace, Brick
Sidewall Composition, Temperature Range 500°C to 1500°C
| Model |
Independent
Controller |
Electrical
Volts,
Hz, 1Ø |
Watts |
Interior
Dimensions
W X D X H in" (mm) |
Exterior
Dimensions
W X D X H in" (mm) |
Ship
Weight
lbs (kg) |
| BF51333C |
CC58125C |
208/240V,
50/60Hz |
5900 |
6"(152)x12"(305)x5"(127) |
25"(635)x29"(736)x26"(660) |
440
(200) |
Controllers
Optional RS485 Digital Communications Port
RS485 Digital communications port available as an option. Allows
controller to be connected to a PC for remote monitoring and
control of the furnace. Up to 30 units can be connected to one
PC.
1500°C Digital, Single Setpoint Controller
Control console is fully wired and includes advanced microprocessor-based
digital control, a solid-state power module, on/off circuit breaker
and thermocouple input jack. Includes microprocessor-based PID
control (proportional, integral, derivative), single segment,
single setpoint, 1 ramp to setpoint. Built-in adjustable high
limit overtemperature protection. Simultaneous LED display of
actual temperature vs. setpoint. May be configured to display
temperature in either °C or °F.
Option P 1500°C Digital Single Program,
Multiple Segment Programmable Controller
Control console includes advanced microprocessor-based digital
control, a solid-state power module, on/off circuit breaker and
thermocouple input jack. Includes microprocessor-based PID control
(proportional, integral, derivative), single program with multiple
segments for ramp (up and down) and dwell (timed hold) temperature
control. Built-in adjustable high limit overtemperature protection.
Simultaneous LED display of actual temperature vs. setpoint.May
be configured to display temperature in either °C or °F.
Option B Overtemperature Control (OTC)
Adjustable digital overtemperature control, factory installed on
selected control consoles with "B" designation; see
chart. Protects furnace and load in the event of primary control
circuit failure. Overrides main controller, assumes temperature
control and shuts off power to furnace if high limit is reached.
Manual re-set required for safety. Operates via magnetic contacts
through signal from independent thermocouple.
| Model |
CC58125C |
CC58125BC |
CC58125PC |
CC58125PBC |
| Digital |
|
|
|
|
| With
Programmer |
|
|
|
|
| With
Overtemp Control |
|
|
|
|
| Electrical
Volts, Hz |
208/240V,
50/60Hz |
208/240V,
50/60Hz |
208/240V,
50/60Hz |
208/240V,
50/60Hz |
| Maximum
Amps |
60 |
60 |
60 |
60 |
Exterior
Dimensions
WxDxH in" (mm) |
14"(355)x19"(483)
x10"(254) |
14"(355)x19"(483)
x10"(254) |
14"(355)x19"(483)
x10"(254) |
14"(355)x19"(483)
x10"(254) |
| Ship
Weight lbs (kg) |
35
(16) |
35
(16) |
35
(16) |
35
(16) |
Notes:
- Power cord and interconnecting wiring supplied by customer.
- Fitted silicon-carbide hearthplate protects interior from spills.
- Type "R" thermocouple integrated into chamber backwall, top.
Includes 10' compensated thermocouple lead wire and polarized
plug.
- Maximum weight capacity is 0.5 pounds per square inch of interior
floor surface.